MS-DMT Guide v1.04
Released 05-30-2014
Uses the proper CAT PTT ON and OFF commands for the
DATA port if CAT PTT is selected vs. Pins 6 (DPTT) and 8
(GND) of the KCT-39 cable for hardware PTT.
Requires the “Enhanced PC Control" firmware v1.32 update
or later. The radio is being controlled in Jupiter mode, thus
full manual control is available.
Sent test build to AAM4SC. LINE selected for DATA TX and
back to MIC on RX, has potential of working.
Omni VI PTT is supported via Ten Tec extended command.
Radio Address is factory 0xE0h
Omni VI Plus. PTT is supported via Ten Tec extended
command.
Radio Address is factory 0x04h
Paragon II. PTT is supported via Ten Tec extended command.
Radio Address is factory 0x2Ch
For use for OMNI VII TT588 and TT588AT in REMOTE MODE,
a new protocol that places the TT588 series radio into a
hands off operation by the user.
OMNI VII REMOTE MODE as documented in Model 588
Programmers Reference Guide Rev 1.0. To enter REMOTE
MODE hold down digit 2 on the band stack keyboard until
the firmware version string and REMOTE appears on the
display.
Line Port selected before TX and MIC on RX
Also use for TT599AT and TT539.